Details:
Item | Tech Spec |
NetEngine 8000 M1A Basic Configuration | Includes M1A Chassis, Fixed Interface(4*10GE + 12*GE),2*DC Power |
Switching capacity | 352G bit/s |
Forwarding Performance | 72 Mpps |
Redundant power supply | Supports two power input redundancy backup |
Redundant fans | 2+1, Short-term running when a single fan becomes invalid at the ambient temperature of 40°C (104°F) |
Breakout supported | No |
Interface rate auto-sensing supported | Yes |
RTU supported | Yes 88036KAT: NetEngine 8000 M1A basic configuration upgrade package (upgrade from 52G to 86G) For details about how to use the RTU, see "Installation - License Usage Guide". |
Typical power consumption [W] | 74.84 W |
Typical heat dissipation [BTU/hour] | 242.81 BTU/hour |
MTBF [year] | 35.99 year |
MTTR [hour] | 2 hour |
Availability | 0.99999 |
Power supply mode | DC |
Rated input voltage [V] | -48 V/-60 V |
Input voltage range [V] | -38.4 V to -72 V |
Maximum input current [A] | 4 A |
Rated output power [W] | 170 W |
Maximum input cable size [mm²] | 4mm^2 |
Front-end circuit breaker/fuse [A] | ≥4 A |
Heat dissipation | Air cooling |
Airflow direction | left-to-right direction |
Noise at normal temperature (acoustic power) [dB(A)] | < 55 dB(A) |
Weight without packaging (base configuration) [kg] | 3.9 kg |
Weight with packaging (base configuration) [kg] | 5.2 kg |
Cabinet installation standards | ETSI(21-inch);IEC(19-inch); IMB(3U);F01M50 Outdoor Cabinet |
Dimensions without packaging (H x W x D) [mm] | 44.45 mm x 442 mm x 220 mm |
Dimensions with packaging (H x W x D) [mm] | 255 mm x 585 mm x 390 mm |