Details:
Product | NetEngine 8000 F1A |
Weight without packaging (full configuration) | DC: 8.4 kg(18.52 lb) | AC: 8.75 kg(19.29 lb) |
Cabinet installation standard | IEC 19-inch |
Typical power consumption | 325 W |
Typical heat dissipation | 1054.44 BTU/Hour |
DC input voltage | Input voltage range:-40V to -72V | Input rated voltage: -48V/-60V |
AC input voltage | Input voltage range: 90 V to 290 V | Input rated voltage: 100 V to 240 V |
MTBF | DC: 25.52 years | AC: 25.65 years |
MTTR | 0.5 hour |
Availability | 0.9999996143 |
Redundant fans | 3+1,if a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C. |
Redundant power supply | Supports two power input redundancy backup |
Forwarding performance | 453Mpps |
Switching capacity | 2.4T bit/s |
Long-term operating temperature | Front to back (port-side intake): –5°C to +45°C Back to front (port-side exhaust): –5°C to +40°C Remarks: The temperature change rate limit is 30°C/hour |
Short-term operating temperature | N/A |
Restriction on the operating temperature variation rate | Restriction on the temperature variation rate: 30°C/hour (86°F/hour). |
Storage temperature | -40 °C to 70 °C (-40°F to 158°F) |
Long-term operating relative humidity | 5% to 90% RH, non-condensing |
Short-term operating relative humidity | 5% to 95% RH, non-condensing |
Relative storage humidity | 5% to 95% RH, non-condensing |
Long-term operating altitude | Front to back (port-side intake): 1800 meters at the temperature of 45°C Back to front (port-side exhaust): 1800 meters at the temperature of 40°C <= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].) |
Storage altitude | Lower than 5000 meters(16404 ft.) |
Regulatory compliance | EMC EN 55032 CISPR 32 EN 55024 CISPR 24 |